Professional Data Center Equipment Supplier- Tuxin

Tuxin is a professional manufacturer which specialized in Data Center Solution, Server rack, Network cabinet, Outdoor cabinet, Wall Cabinet, Open Frame Rack, Basic and Smart PDU and Communication equipment products over 10 years.

What Is Data Center Equipment or Containment ?

  • Tuxin Data center equipment is a method used to optimize the cooling efficiency of data centers. By managing the flow of hot and cold air, it ensures that IT equipment is cooled effectively, reducing energy consumption and prolonging the life of the equipment.
  • Tuxin Data center solution purpose is to improve the utilisation rate of the cold air , save energy and reduce operation cost through airflow management, reduce the PUE value of the whole data centre, and build an optimized IT operation micro-environment;
  • Tuxin’s Data center equipment consists of modular server rack, Roof ceiling system, Aisle sliding doors, integrated wiring devices and functional accessory systems.

The Backbone of Data Center Containment -Cold or Hot Aisle Containment

Hot Aisle Containment

 

  • Cold Aisle Containment (CAC):

Cold aisles are typically equipped with perforated raised floor to allow conditioned air from the cooling system to rise up into the intake of the servers.

The front of racks face the cold aisle. This means that servers draw in the cold air from this aisle. Enclosing cold aisle  ensure that the cold air is directed straight into the servers’ intakes without any mixing with the hot air..

  • Hot Aisle Containment (HAC):

This design ensures that the hot exhaust air from servers is directed towards the hot aisle, where it can be returned to the cooling units and be reconditioned without any mixing with the hot air.

The backs of the racks, where hot air is exhausted from servers, face the hot aisle.

The Heart of Data center equipment -Cold Air Containment Syetems

  • Tuxin Data Center Equipment Application
  1. Tuxin’s Single-row and dual-row cold data center containment is suitable for small and medium-sized data centers, widely used in branch data centre deployment needs
  2. Multiple module data center groups can be used, suitable for large-scale IDC server room, data center; widely used in government data center, financial and banking systems, education systems, medical institutions, telecommunications and other industries.

Cold Air Containment System

Dual-row Aisle

Dual-row Aisle

  •  Why Choose Tuxin Data Center Equipment Solution?

Tuxin Data Center Equipment Solution Advantages:

  1. Modular design:Most parts of the Data center equipment components are designed by modular. Each unit (Server racks, Roof ceiling and sliding door) can be independently installed and removed, and can be connected with adjacent units, which allows quick deployment on site to meet the changing needs or future expansion. The whole system of all the installations are processed through the factory into a modular form to the site.
  2. Good sealing: Hot and cold aisle roof ceiling of the unit module between the connection is tight, can effectively prevent airflow leakage. The use of good sealing between the door frame can prevent the cold air leakage of the cold data center containment.
  3. Strong security: The cold aisle roof ceiling frame is made of 1.5mm steel plate, and the internal double-layer toughened glass or White polycarbonate plastic, Light transmittance up to 82%, it will not burn to produce flames or smoke when it meets with the fire alarm. And linked with the fire system.
  4. High intelligent degree:Flip design on roof ceiling, to be connected with fire protection through intelligent control box. The roof ceiling will automatically open, when fire signal received.  And fire-extinguishing gas will come into aisle, without conflict to the existing fire protection system.

The Backbone of Data Centers-Server Racks

 

Server Racks

Technical Specifications
Standard DIN41491, DIN41494, EIA/ECA-310-E, IEC/EN 62368-1 ,RoHS
Material SPCC Cold Rolled Steel

19″ rails:2.0mm, frame:1.5mm  front door: 1.5mm

others:1.2mm

Loading capacity 1500-2000KG
IP degree IP20
Shipping Option: Assembly unit or flat packed
Capacity 15U-52U
Width 600,800, 750
Depth 600,800,1000,1070,1100,1200
Certificates CE ROHS
warranty 2years
Leading time 25 to 30days

Tuxin Server Racks Feathers:

1.Single flat mesh front door with hexagonal hole with 74.8% ventilation rate

2.Split flat mesh rear door with hexagonal hole with 74.8% ventilation rate

3.1500KG-2000KG loading capacity

4.2 pairs of side panels,Side panel with latches and key lock. Split design (top & bottom) for easy handling and installations.

5.4 x (19”) vertical mounting rails Meets EIA310 standard compliant 483mm,The U markings are printed on both (front & rear) side on each EIA rails.

6.Adjustable leveling feets and Heavy duty caster

7.2 x Vertical PDU / cable management tray ready for dual PDU mounting

8.Baying kit, 4 pcs (bundled with rack)

Server Racks Feathers 

Tuxin Data Center Equipment- Roof Ceiling

rotary Roof Ceiling

Fixed Roof Ceiling

control system

Tuxin Data Center Equipment- Light Systems

Light Systems

Tuxin Data Center Equipment- Sliding Door

  • Data Center Equipment- Mechnical Doors (Customized) 

Mechnical Doors (Customized)

  • Data Center Equipment- Automatic Sliding Doors (Customized)

Automatic Sliding Doors (Customized)

Tuxin Data Center Success

Tuxin Data Center

The Main Products of Tuxin Cabinet Are:

  • Data center equipment products
  • Cold/ Hot aisle data center containment
  • Server racks and Network cabinet
  • Open racks
  • Wall mounted server cabinets
  • Basic PDU and Smart PDU
  • IP55 to IP65 Outdoor cabinet

 